We just deployed a 6513E with a Sup720. It is running IOS, but when it reboots it goes straight into rommon and you need to type boot to get it to load... once you do that it boots fine...
My worry is that this site has power issues... Here is some output: 6513#sh boot BOOT variable = sup-bootdisk:s3223-ipbase_wan-mz.122-18.SXF8.bin,12; CONFIG_FILE variable does not exist BOOTLDR variable does not exist Configuration register is 0x2102 Standby is not present. 6513#sh log [output truncated] 00:01:01: RP: Currently running ROMMON from S (Gold) region 00:01:16: %SYS-6-CLOCKUPDATE: System clock has been updated from 02:14:42 UTC Wed Apr 23 2008 to 19:14:42 PDT Tue Apr 22 2008, configured from console by console. 00:01:16: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan 00:01:17: %SYS-5-CONFIG_I: Configured from memory by console 00:01:19: %SYS-5-RESTART: System restarted -- Cisco Internetwork Operating System Software IOS (tm) s3223_rp Software (s3223_rp-IPBASE_WAN-M), Version 12.2(18)SXF8, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2007 by cisco Systems, Inc. Compiled Fri 02-Mar-07 21:29 by tinhuang 00:01:19: %MFIB_CONST_RP-6-REPLICATION_MODE_CHANGE: Replication Mode Change Detected. Current system replication mode is Ingress 00:00:05: %SYS-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output. 00:00:09: %OIR-SP-6-CONSOLE: Changing console ownership to route processor 00:00:09: %SYS-SP-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output. Firmware compiled 20-Feb-07 14:12 by integ Build [100] 00:01:11: %SPANTREE-SP-5-EXTENDED_SYSID: Extended SysId enabled for type vlan 00:01:19: %SYS-SP-5-RESTART: System restarted -- Cisco Internetwork Operating System Software IOS (tm) s3223_sp Software (s3223_sp-IPBASE_WAN-M), Version 12.2(18)SXF8, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2007 by cisco Systems, Inc. Compiled Fri 02-Mar-07 21:28 by tinhuang 00:01:19: SP: Currently running ROMMON from S (Gold) region 00:01:20: %MLSM-6-MMLS_MODE_CHANGE: MMLS: Replication Mode Changed to Egress mode (Oir event) 00:01:21: %OIR-SP-6-INSPS: Power supply inserted in slot 1 00:01:21: %C6KPWR-SP-4-PSOK: power supply 1 turned on. 00:01:21: %OIR-SP-6-INSPS: Power supply inserted in slot 2 00:01:21: %C6KPWR-SP-4-PSOK: power supply 2 turned on. 00:01:21: %C6KPWR-SP-4-PSREDUNDANTBOTHSUPPLY: in power-redundancy mode, system is operating on both power supplies. 00:01:23: %C6KENV-SP-4-FANHIOUTPUT: Version 2 high-output fan-tray is in effect 00:01:29: %DIAG-SP-6-RUN_MINIMUM: Module 7: Running Minimal Diagnostics... 00:01:41: %MLSM-6-MMLS_MODE_CHANGE: MMLS: Replication Mode Changed to Ingress mode (Oir event) 00:01:40: %DIAG-SP-6-DIAG_OK: Module 7: Passed Online Diagnostics 00:01:42: %DIAG-SP-6-RUN_MINIMUM: Module 2: Running Minimal Diagnostics... 00:01:43: %OIR-SP-6-INSCARD: Card inserted in slot 7, interfaces are now online 00:01:50: %DIAG-SP-6-DIAG_OK: Module 2: Passed Online Diagnostics Any ideas? Jonathan _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/