On Oct 15, 2008, at 9:35 AM, Roy wrote:
Just because its a point to point circuit doesn't mean one side has to
have internal clocking. This is only true if the circuit is copper
all
the way. There are lots of reasons that the telco would have its own
equipment installed on the circuit and you would need network timing.
I'll second what Roy says. Both sides should be clocking from the
network. The T-1 is going to get muxed and/or go through a telco
digital cross connect so the telco will be providing their clock on
the line.
--Chris
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/