On Tue, 2009-03-10 at 11:32 +0100, Andrew Yourtchenko wrote: > if it is merely a new standby that is coming up, the active should not > stop forwarding the traffic.
That's what I would've assumed too. :-) I do seem to remember that we've seen this before though, when we had random reboots (CSCse15099 if I remember correctly) of secondary units resulting in downtime. > I'd watch out for "logging standby" - I vaguely remember there were > some issues where the newly coming up box would try to send the > traffic with the wrong IP/MAC and/or send the gratuitous arp with the > wrong info in there. > > Especially may be true if you are bringing up primary as standby - at > this moment the secondary/active is forwarding the traffic using the > primary's mac addresses. Standby logging is disabled on all contexts, so this shouldn't be the issue. Of course if the module coming up sends out gratuitous ARPs this could break things with the way PIX/FWSM/ASA does HA, using the same MAC-address. I had thought that the unit coming up would start by looking at the failover interface(s) to see if there is already an active unit, and then start acting as active/standby depending of what it hears. Otherwise a crashing/rebooting primary unit would always introduce downtime when coming up again. > Of course, interesting would be to check if indeed this is on all the > contexts or only some of them, etc. The log buffer (logging errors) on the contexts on the standby unit (which is the configured primary) didn't say "' >From the sys context on the standby: Mar 09 2009 16:41:04: %FWSM-4-411003: Interface statefullfailover, changed state to administratively up Mar 09 2009 16:41:05: %FWSM-5-504001: Security context admin was added to the system ... Mar 09 2009 16:41:07: %FWSM-5-504001: Security context sample was added to the system Mar 09 2009 16:41:26: %FWSM-1-709006: (Primary) End Configuration Replication (STB) Mar 09 2009 16:42:02: %FWSM-6-210022: LU missed 4837568 updates >From one of the contexts, still the standby unit: Mar 09 2009 16:41:35: %FWSM-1-105006: (Primary) Link status 'Up' on interface internet Mar 09 2009 16:41:35: %FWSM-1-105003: (Primary) Monitoring on interface internet waiting Mar 09 2009 16:41:35: %FWSM-1-105006: (Primary) Link status 'Up' on interface aars_pro Mar 09 2009 16:41:35: %FWSM-1-105003: (Primary) Monitoring on interface aars_pro waiting Mar 09 2009 16:41:35: %FWSM-1-105006: (Primary) Link status 'Up' on interface inside Mar 09 2009 16:41:35: %FWSM-1-105003: (Primary) Monitoring on interface inside waiting Mar 09 2009 16:41:35: %FWSM-1-105006: (Primary) Link status 'Up' on interface aars_interfw Mar 09 2009 16:41:35: %FWSM-1-105003: (Primary) Monitoring on interface aars_interfw waiting Mar 09 2009 16:41:44: %FWSM-1-105004: (Primary) Monitoring on interface internet normal Mar 09 2009 16:41:44: %FWSM-1-105004: (Primary) Monitoring on interface aars_pro normal Mar 09 2009 16:41:44: %FWSM-1-105004: (Primary) Monitoring on interface inside normal Mar 09 2009 16:41:44: %FWSM-1-105004: (Primary) Monitoring on interface aars_interfw normal So the contexts weren't really activated (with "Up" interfaces) during all the downtime, just at the end. To me that seems to suggest that it's not just simply that it "steals" the traffic for the interfaces. It seems we have to try and replicate it in the lab to find out what actually happened. :-) Thank you for the input. Regards, Peter _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/