Hello all,

 

With an ASA running a redundant physical interface pair for the Inside
interface, each link connected to a separate switch which is connected
to a separate router, and everything running EIGRP, I get multiple
routes (2) to the same destination subnet, one for each of the connected
routers.  This is obviously causing problems, and I can't seem to find a
way to resolve it.  Setting delay on the physical interfaces doesn't
seem to take effect, and there is no variance sub-command so I can't
just force one route.  This needs to function in a redundant situation,
as in if I lose a router or switch everything will continue to function
(hence the redundant interface).  I tried google and cisco and found
nothing of any significance...anyone got any ideas?

 

Thanks!

 

 

 

Jason Link

Network Engineer

Wisconsin Hospitality Group / RSC

Office 414-259-8484

Cell 414-403-3110

 