In most cases, a topology like this will have the ONS's synced to GPS time, or 
some accurate clock  (or line clocking if your ONS connects to another 
provider, but GPS is typically preferred) and then I would DEFINITELY use line 
clocking on the PA-MC-T3, unless you have the capability through a clock card 
to connect the 7204 to the same timing source as the ONS uses (ie: GPS derived 
clock)  
Whenever possible, keep all devices in sync with a common clock




----- Original Message ----- 

From: "Natambu Obleton" <[email protected]> 
To: [email protected] 
Sent: Tuesday, June 5, 2012 2:17:54 PM 
Subject: [c-nsp] CT3 Timing issue 

Hello, 

I have a customer with a 2xT1 MPPP link to my 7204. The T1 come in to the 7204 
on different PA-MC-T3 cards. The PA-MC-T3 cards plug into my ONS 15454 SONET 
network. When I have timing set on the CPE to one of the T1s the other T1 gets 
slips and vice versa. Both of the PA-MC-T3 are set for internal timing. 
Shouldn't their timing be the same or should I have these setup for line 
timing? Thanks. 

-- 

Natambu Obleton, CISSP CCNA 
Senior Network Engineer 
FastTrack Communications, Inc. 
970.828.1009 

_______________________________________________ 
cisco-nsp mailing list [email protected] 
https://puck.nether.net/mailman/listinfo/cisco-nsp 
archive at http://puck.nether.net/pipermail/cisco-nsp/ 
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to