On 06/06/2012, at 12:53 PM, Natambu Obleton wrote:

> I changed the PA-MC-T3s to line clocking, but still getting errors. If I 
> connect both T1s to the same DS3, everything is fine. It's only if I spread 
> the MLPPP T1's across the PA-MC-T3. I don't have the spread them, but it does 
> the customer some redundancy. The CPE is an Adtran TA908e. 
> 
> Since I know the Adtran uses the same clock for both T1s and the PA-MC-T3's 
> aren't, I have changed the T1 ports on the PA-MC-T3 to line and changed the 
> adtran to internal and the slips have stopped. I do feel better with the 
> PA-MC-T3 set to line on the DS3. Common clock achieved, sorta. :)

Hi Natambu,

How many clock sources do you have on your network?!

Normally the carrier provides the clock and all your gear should sync to 
that....

Andrew