I changed the PA-MC-T3s to line clocking, but still getting errors. If I 
connect both T1s to the same DS3, everything is fine. It's only if I spread the 
MLPPP T1's across the PA-MC-T3. I don't have the spread them, but it does the 
customer some redundancy. The CPE is an Adtran TA908e. 

Since I know the Adtran uses the same clock for both T1s and the PA-MC-T3's 
aren't, I have changed the T1 ports on the PA-MC-T3 to line and changed the 
adtran to internal and the slips have stopped. I do feel better with the 
PA-MC-T3 set to line on the DS3. Common clock achieved, sorta. :)




On Jun 5, 2012, at 4:41 PM, Natambu Obleton wrote:

> Yeah. We have external BITS clocks, and secondary timing from the local 
> exchange carrier. I will try line timing after hours tonight. If I terminate 
> the T1's the same PA-MC-T3 I don't have slips, so the PA-MC-T3 must have a 
> clock on the card....
> 
> --
>  
> Natambu Obleton, CISSP CCNA
> Senior Network Engineer
> FastTrack Communications, Inc.
> 970.828.1009
> 
> -----Original Message-----
> From: Walter Keen [mailto:[email protected]] 
> Sent: Tuesday, June 05, 2012 3:59 PM
> To: Natambu Obleton
> Cc: [email protected]
> Subject: Re: [c-nsp] CT3 Timing issue
> 
> In most cases, a topology like this will have the ONS's synced to GPS time, 
> or some accurate clock  (or line clocking if your ONS connects to another 
> provider, but GPS is typically preferred) and then I would DEFINITELY use 
> line clocking on the PA-MC-T3, unless you have the capability through a clock 
> card to connect the 7204 to the same timing source as the ONS uses (ie: GPS 
> derived clock) Whenever possible, keep all devices in sync with a common clock
> 
> 
> 
> 
> ----- Original Message ----- 
> 
> From: "Natambu Obleton" <[email protected]>
> To: [email protected]
> Sent: Tuesday, June 5, 2012 2:17:54 PM
> Subject: [c-nsp] CT3 Timing issue 
> 
> Hello, 
> 
> I have a customer with a 2xT1 MPPP link to my 7204. The T1 come in to the 
> 7204 on different PA-MC-T3 cards. The PA-MC-T3 cards plug into my ONS 15454 
> SONET network. When I have timing set on the CPE to one of the T1s the other 
> T1 gets slips and vice versa. Both of the PA-MC-T3 are set for internal 
> timing. Shouldn't their timing be the same or should I have these setup for 
> line timing? Thanks. 
> 
> -- 
> 
> Natambu Obleton, CISSP CCNA
> Senior Network Engineer
> FastTrack Communications, Inc. 
> 970.828.1009 
> 
> _______________________________________________
> cisco-nsp mailing list [email protected] 
> https://puck.nether.net/mailman/listinfo/cisco-nsp
> archive at http://puck.nether.net/pipermail/cisco-nsp/ 
> 
> _______________________________________________
> cisco-nsp mailing list  [email protected]
> https://puck.nether.net/mailman/listinfo/cisco-nsp
> archive at http://puck.nether.net/pipermail/cisco-nsp/


_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to