Daniel, Pshem: thanks for clearing this up!
regards, Martin 2013/6/21, Pshem Kowalczyk <[email protected]>: > Hi, > > ME3600x can be used for mobile backhaul. If you do E1/T1 or STM > emulation - you have to provide correct clocking to both sides. One > end would normally take the clocking of some external source (for > example using the BITS port) and the other one would relay on > something like 1588v2 (or syncE) to provide the synchronisation onto > the E1/T1 circuit. > > kind regards > Pshem > > > On 21 June 2013 06:43, Martin T <[email protected]> wrote: >> Hi, >> >> Cisco ME-3600X switches support RJ45 BITS(Building Integrated Timing >> Source) interface which can be used for sending and receiving the E1 or >> T1 >> timing signals. As I understand, timing signals in case of SDH/SONET are >> needed in each node to keep the transmit and receive rates unified all >> over >> the network. In which scenario would somebody want to use ME-3600X for >> providing this clock signal? In addition, why would one want to receive >> E1/T1 timing signal on an Ethernet switch? >> >> >> regards, >> Martin >> _______________________________________________ >> cisco-nsp mailing list [email protected] >> https://puck.nether.net/mailman/listinfo/cisco-nsp >> archive at http://puck.nether.net/pipermail/cisco-nsp/ > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/
