You appear to have the inline power module for ip phones.  I had a
problem once on a server where I disabled the power on the port and this
resolved the errors.

C6509> (enable) set port inlinepower 2/26 off

  Dave

Patrick Donlon wrote:
> 
> And here's the show port I forgot!!
> 
> (enable) sh port 2/26
> Port  Name               Status     Vlan       Duplex Speed Type
> ----- ------------------ ---------- ---------- ------ ----- ------------
>  2/26 Temp Driver server connected  990          full   100 10/100BaseTX
> 
> Port  AuxiliaryVlan AuxVlan-Status     InlinePowered     PowerAllocated
>                                    Admin Oper   Detected mWatt mA @42V
> ----- ------------- -------------- ----- ------ -------- ----- --------
>  2/26 none          none           -     -      -        -     -
> 
> Port  Security Violation Shutdown-Time Age-Time Max-Addr Trap     IfIndex
> ----- -------- --------- ------------- -------- -------- -------- -------
>  2/26 disabled  shutdown             0        0        1 disabled      51
> 
> Port  Num-Addr Secure-Src-Addr   Age-Left Last-Src-Addr
> Shutdown/Time-Left
> ----- -------- ----------------- -------- -----------------
----------------
> --
>  2/26
>                  -        -                 -        -         -
> 
> Port     Broadcast-Limit Broadcast-Drop
> -------- --------------- --------------------
>  2/26                  -                    0
> 
> Port   Send FlowControl    Receive FlowControl   RxPause TxPause
Unsupported
>        admin    oper       admin    oper                         opcodes
> -----  -------- --------   -------- --------     ------- -------
-----------
>  2/26  off      off        off      off          0       0       0
> 
> Port  Status     Channel              Admin Ch
>                  Mode                 Group Id
> ----- ---------- -------------------- ----- -----
>  2/26 connected  auto silent             68     0
> 
> Port  Align-Err  FCS-Err    Xmit-Err   Rcv-Err    UnderSize
> ----- ---------- ---------- ---------- ---------- ---------
>  2/26     154661     138931          0          0      6246
> 
> Port  Single-Col Multi-Coll Late-Coll  Excess-Col Carri-Sen Runts    
Giants
> ----- ---------- ---------- ---------- ---------- --------- ---------
------
> ---
>  2/26          0          0          0          0         0     30531
> 1
> 
> Port  Last-Time-Cleared
> ----- --------------------------
> ""Patrick Donlon""  wrote in message
> [EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> > Hi Everyone
> >
> >  I trying to find some information on some Ethernet errors that I see on
a
> >  port, see the text below. The machine is an RS6000 and was experiencing
> > some
> >  performance problems, the NIC was set to auto negotiation and there were
> > the
> >  usual errors. The port and NIC are now both fixed and the errors are
> >  increasing steadily, I've had a good search on the CCO but I can't find
> any
> >  explanation of what causes the errors, any advice will be appreciated
> >
> >  Regards
> >
> >  Patrick
-- 
David Madland
Sr. Network Engineer
CCIE# 2016
Qwest Communications Int. Inc.
[EMAIL PROTECTED]
612-664-3367

"Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=33702&t=33687
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to