Dave tried that one first as I thought it was the most interesting, but
sadly

(enable) set port inline 2/26 off
Feature not supported on module 2.

I'll go back to basics first Ole.

Thanks for the replies

Pat

""MADMAN""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> You appear to have the inline power module for ip phones.  I had a
> problem once on a server where I disabled the power on the port and this
> resolved the errors.
>
> C6509> (enable) set port inlinepower 2/26 off
>
>   Dave
>
> Patrick Donlon wrote:
> >
> > And here's the show port I forgot!!
> >
> > (enable) sh port 2/26
> > Port  Name               Status     Vlan       Duplex Speed Type
> > ----- ------------------ ---------- ---------- ------ ----- ------------
> >  2/26 Temp Driver server connected  990          full   100 10/100BaseTX
> >
> > Port  AuxiliaryVlan AuxVlan-Status     InlinePowered     PowerAllocated
> >                                    Admin Oper   Detected mWatt mA @42V
> > ----- ------------- -------------- ----- ------ -------- ----- --------
> >  2/26 none          none           -     -      -        -     -
> >
> > Port  Security Violation Shutdown-Time Age-Time Max-Addr Trap
IfIndex
>
> ----- -------- --------- ------------- -------- -------- -------- -------
> >  2/26 disabled  shutdown             0        0        1 disabled
51
> >
> > Port  Num-Addr Secure-Src-Addr   Age-Left Last-Src-Addr
> > Shutdown/Time-Left
> > ----- -------- ----------------- -------- -----------------
> ----------------
> > --
> >  2/26
> >                  -        -                 -        -         -
> >
> > Port     Broadcast-Limit Broadcast-Drop
> > -------- --------------- --------------------
> >  2/26                  -                    0
> >
> > Port   Send FlowControl    Receive FlowControl   RxPause TxPause
> Unsupported
> >        admin    oper       admin    oper                         opcodes
> > -----  -------- --------   -------- --------     ------- -------
> -----------
> >  2/26  off      off        off      off          0       0       0
> >
> > Port  Status     Channel              Admin Ch
> >                  Mode                 Group Id
> > ----- ---------- -------------------- ----- -----
> >  2/26 connected  auto silent             68     0
> >
> > Port  Align-Err  FCS-Err    Xmit-Err   Rcv-Err    UnderSize
> > ----- ---------- ---------- ---------- ---------- ---------
> >  2/26     154661     138931          0          0      6246
> >
> > Port  Single-Col Multi-Coll Late-Coll  Excess-Col Carri-Sen Runts
> Giants
> > ----- ---------- ---------- ---------- ---------- --------- ---------
> ------
> > ---
> >  2/26          0          0          0          0         0     30531
> > 1
> >
> > Port  Last-Time-Cleared
> > ----- --------------------------
> > ""Patrick Donlon""  wrote in message
> > [EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> > > Hi Everyone
> > >
> > >  I trying to find some information on some Ethernet errors that I see
on
> a
> > >  port, see the text below. The machine is an RS6000 and was
experiencing
> > > some
> > >  performance problems, the NIC was set to auto negotiation and there
were
> > > the
> > >  usual errors. The port and NIC are now both fixed and the errors are
> > >  increasing steadily, I've had a good search on the CCO but I can't
find
> > any
> > >  explanation of what causes the errors, any advice will be appreciated
> > >
> > >  Regards
> > >
> > >  Patrick
> --
> David Madland
> Sr. Network Engineer
> CCIE# 2016
> Qwest Communications Int. Inc.
> [EMAIL PROTECTED]
> 612-664-3367
>
> "Emotion should reflect reason not guide it"