I knew it should have been easy - I just got myself stuck in thinking 
about stems rather than REXX variables.

That will do the job fine.

Regarding your question: This is a server that is, in fact, running in a 
pipeline. What I am doing with this command is to load configuration 
control information that will be used to process every message passed to 
the pipeline server code by the master pipe. 

This particular server will receive request for tape 
mounts/dismounts/queries on STK equipment and then process these on MVS 
over TCPIP, passing the results to the requesting user. The particular 
control file will translate a symbolic tape pool into the real STK pool 
number.

Thanks for your help.

Colin Allinson


Rob van der Heij <[EMAIL PROTECTED]> wrote :-

>> I have a file where each record contains 2 words - a key and a value.
>>
>> What I want to do is to load a stem indexed on the key. Ideally, the 
rest
>> of the stem would have a default value. ie

> Something like this?

> stub. = 'Blank'
> 'PIPE (end \ name CGA.EXEC:3)',
>    '\ literal 23 Yellow, 46 Red',
>    '| split ,',
>    '| spec ,/STUB., 1 w1 n ,/, n w2 n',
>    '| cons',
>    '| varload direct nocomment'

> do i = 0 to 69 by 23
>   say right(i,3) stub.i
> end

> Master Plumber's Conduct Guidelines require that I ask you why you
> want stuff in Rexx variables at all. What is the real problem you want
> to solve, and could we maybe help you solve that one instead of
> tempting you into Rexx coding ;-)

> Rob



Colin Allinson
Technical Manager - VM Systems Support
Operating Systems Services
Amadeus Data Processing GmbH
T: +49 (0)8122 43 4975
F: +49 (0)8122 43 3260
[EMAIL PROTECTED]
www.amadeus.com



IMPORTANT  -  CONFIDENTIALITY  NOTICE  - This e-mail is intended only for 
the use of the individual or entity shown above as addressees . It may 
contain information which is privileged, confidential or otherwise 
protected from disclosure under applicable laws .  If the reader of this 
transmission is not the intended recipient, you are hereby notified that 
any dissemination, printing, distribution, copying, disclosure or the 
taking of any action in reliance on the contents of this information is 
strictly prohibited.  If you have received this transmission in error, 
please immediately notify us by reply e-mail or using the address below 
and delete the message and any attachments from your system . 

Amadeus Data Processing GmbH 
Geschäftsführer: Eberhard Haag 
Sitz der Gesellschaft: Erding 
HR München 48 199 
Berghamer Strasse 6 
85435 Erding 
Germany

Reply via email to