Am most pleased to advise we seem to have fixed the problem in our Standard 
Horizon WS150.  In the masthead anemometer, seems the solder joints to the 
circuit boards of the connecting wires were corroded.  Two wires broke off when 
jiggled and the third was hanging on by one wire.  The wires are extremely 
light gauge, so no wonder we were having erratic readings!!!.  Resoldered all 
to the circuit board after cutting off the corroded wire.  Very precise process 
due to very small wire and tight tolerances of the circuit board.  Redid the 
linearization and recalibrated – All is well.  So our advice is if your 
instruments are older and giving erratic readings it is most likely due to 
resistance of corroded solder joints so start there first

 

 

John and Maryann