Adding on a bit... On 23/10/2017 12:45, Karsten Dreifus wrote:
Hi Paul, I am using the dev version coot 0.8.9-pre (revision 6956). Trying to use the Ramachandran plot atom-selection function. I used "/1/A/10-20" But does not filter. Any working examples?
No. Its not functional. It is a placeholder and was meant to be filled but there is a new Ramachandran coming where it works ;-) In Paul's hands when... until then the current widget should probably be removed.
B
Many thanks, Karsten (from http://www2.mrc-lmb.cam.ac.uk/personal/pemsley/coot/web/docs/coot.html#Ball-and-Stick-Representation )
-- *************************************************** Dr. Bernhard Lohkamp Associate Professor/Docent Div. Molecular Structural Biology Dept. of Medical Biochemistry and Biophysics (MBB) Karolinska Institutet S-17177 Stockholm Sweden phone: (+46) 08-52487695 fax: (+46) 08-327626 email: [email protected]