I "think" that the reason is that the pump sucks from the right tank. If the high part of the "u" bend is above the tank fittings for the cross over line then the fuel in the left tank that is below the high point of the "u" bend would never get to the right tank and be pumped. There would not be enough head to maintain a siphon.
Once I have the floor boards up, I'll confirm this. The symptoms match exactly another Coupers experience. If indeed it is the "u" bend, it'll be an easy fix. Cheers: Paul N2409H > If the fuel pump is sucking fuel, why would a hi point in the fuel line make > the remaining fuel unusable? After all the fuel pump is 1-2 feet above the > wing tanks. > Dick --------------------------------- to unsubscribe send mailto:[EMAIL PROTECTED] _____________________________________________________________ Check out the new and improved Topica site! http://www.topica.com/t/13