Shutdown command without username and password should work with mixed client
and network server releases.
---------------------------------------------------------------------------------------------------------
Key: DERBY-4786
URL: https://issues.apache.org/jira/browse/DERBY-4786
Project: Derby
Issue Type: Bug
Components: Network Client, Network Server
Affects Versions: 10.6.1.0, 10.5.1.1, 10.4.2.0, 10.4.1.3
Reporter: Mamta A. Satoor
Assignee: Mamta A. Satoor
DERBY-2109 introduced optional parameters username and password to the shutdown
command. But with this fix, the existing shutdown command which does not use
username and password stopped working from client with DERBY-2109 changes
against a network server without DERBY-2109 changes.
This jira is to ensure that existing shutdown command without user name and
password still works fine between different releases of client and network
server(with or without DERBY-2109). The new shutdown command introduced by
DERBY-2109 will work obviosuly only on client and server with DERBY-2109
changes. For client/server not with DERBY-2109 changes attempting to user use
name and password will get an error.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.