https://issues.apache.org/jira/browse/DERBY-4786?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12905291#action_12905291
]
Kathey Marsden commented on DERBY-4786:
---------------------------------------
Hi Mamta,
With this patch, how does a changed trunk client specifying no user/password
behave with an existing 10.5 server? I am concerned it might hang.
Thanks
Kathey
> Shutdown command without username and password should work with mixed client
> and network server releases.
> ---------------------------------------------------------------------------------------------------------
>
> Key: DERBY-4786
> URL: https://issues.apache.org/jira/browse/DERBY-4786
> Project: Derby
> Issue Type: Bug
> Components: Network Client, Network Server
> Affects Versions: 10.4.1.3, 10.4.2.0, 10.5.1.1, 10.6.1.0
> Reporter: Mamta A. Satoor
> Assignee: Mamta A. Satoor
> Attachments: DERBY4786_patch1_diff.txt
>
>
> DERBY-2109 introduced optional parameters username and password to the
> shutdown command. But with this fix, the existing shutdown command which does
> not use username and password stopped working from client with DERBY-2109
> changes against a network server without DERBY-2109 changes.
> This jira is to ensure that existing shutdown command without user name and
> password still works fine between different releases of client and network
> server(with or without DERBY-2109). The new shutdown command introduced by
> DERBY-2109 will work obviosuly only on client and server with DERBY-2109
> changes. For client/server not with DERBY-2109 changes attempting to user use
> name and password will get an error.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.