And one more time I want to discuss the way kannel currently gets 
information about delivery status.
Not all SMSC's return delivery status in deliver_sm pdu's short_message 
field.
Instead, they use optional fields receipted_message_id and 
receipted_message_id.
I think it also shuld be configurable.


Stipe Tolj wrote:

>>My SMSC also uses C octets.
>>I think sms-id format (hex, dec or c octet) should be configurable (atm
>>only hex and dec).
>>    
>>
>
>agreed, we should take in account that SMSCs may return msg id's that
>are alphanumeric and hence don't fit the decimal or hex rules.
>
>Stipe
>
>[EMAIL PROTECTED]
>-------------------------------------------------------------------
>Wapme Systems AG
>
>Vogelsanger Weg 80
>40470 Düsseldorf
>
>Tel: +49-211-74845-0
>Fax: +49-211-74845-299
>
>E-Mail: [EMAIL PROTECTED]
>Internet: http://www.wapme-systems.de
>-------------------------------------------------------------------
>wapme.net - wherever you are
>
>  
>


-- 
David Chkhartishvili
Tel: 995 99 182418