On Sat, Apr 10, 2021 at 6:41 AM <dufa...@hda.com> wrote:
>
> From: Peter Dufault <dufa...@hda.com>
>
> When the PowerPC shared console baud rate starts at anything other than
> 9600 the termios code will set it to 9600 at the first open.
> ---
>  bsps/powerpc/shared/console/uart.c | 3 +++
>  1 file changed, 3 insertions(+)
>
> diff --git a/bsps/powerpc/shared/console/uart.c 
> b/bsps/powerpc/shared/console/uart.c
> index 41db52f..f30b6a3 100644
> --- a/bsps/powerpc/shared/console/uart.c
> +++ b/bsps/powerpc/shared/console/uart.c
> @@ -536,6 +536,9 @@ BSP_uart_termios_set(int uart, void *p)
>
>    uart_data[uart].ioMode           = ttyp->device.outputUsesInterrupts;
>
> +  /* Convert from the baud number to the "speed_t" termios setting. */
> +  ttyp->termios.c_ispeed = ttyp->termios.c_ospeed = 
> rtems_termios_number_to_baud(uart_data[uart].baud);
break line length <80c

Resend both patches in v2. I have no complaints about the first patch.

> +
>    return;
>  }
>
> --
> 1.8.3.1
>
> _______________________________________________
> devel mailing list
> devel@rtems.org
> http://lists.rtems.org/mailman/listinfo/devel
_______________________________________________
devel mailing list
devel@rtems.org
http://lists.rtems.org/mailman/listinfo/devel

Reply via email to