On Sat, Apr 10, 2021 at 6:41 AM <dufa...@hda.com> wrote: > > From: Peter Dufault <dufa...@hda.com> > > When the PowerPC shared console baud rate starts at anything other than > 9600 the termios code will set it to 9600 at the first open. > --- > bsps/powerpc/shared/console/uart.c | 3 +++ > 1 file changed, 3 insertions(+) > > diff --git a/bsps/powerpc/shared/console/uart.c > b/bsps/powerpc/shared/console/uart.c > index 41db52f..f30b6a3 100644 > --- a/bsps/powerpc/shared/console/uart.c > +++ b/bsps/powerpc/shared/console/uart.c > @@ -536,6 +536,9 @@ BSP_uart_termios_set(int uart, void *p) > > uart_data[uart].ioMode = ttyp->device.outputUsesInterrupts; > > + /* Convert from the baud number to the "speed_t" termios setting. */ > + ttyp->termios.c_ispeed = ttyp->termios.c_ospeed = > rtems_termios_number_to_baud(uart_data[uart].baud); break line length <80c
Resend both patches in v2. I have no complaints about the first patch. > + > return; > } > > -- > 1.8.3.1 > > _______________________________________________ > devel mailing list > devel@rtems.org > http://lists.rtems.org/mailman/listinfo/devel _______________________________________________ devel mailing list devel@rtems.org http://lists.rtems.org/mailman/listinfo/devel