George -
OK..
Measure the voltage at TP-2 (on top of the chassis, just in front of the Passband tuner.) Should measure -1.35 volts with the the Preselector detuned on any band.
Have you tried both Fast and Slow AVC? If no AVC in either position, try swapping the Calibrator tube, 12BA6, with either of the IF tubes, V4 or V5. Something is loading the AVC line. If this doesn't help, try swapping the RF Amp, V1 with another 12BZ6.
Beyond this, you'll have to find what is either loading or shorting the AVC line. Possibly one of the grid resistors of V1, V4 or V5 cracked or open. They can go up in value considerably without affecting the AVC, so unless they are open, look elsewhere.
Let us know what you find.
73, Garey - K4OAH
George wrote:
To add to that it is an 11 tube model (no 12av6)
George NE2I
----- Original Message ----- From: George To: [EMAIL PROTECTED] Sent: Thursday, April 08, 2004 9:00 PM
Subject: [drakelist] R4A AGC inop.
Just bought an r4a and it seems like the agc is not working at all I have to ride the rf gain or I get way too much audio and distortion It has good sensitivity and is spot on frequency wise.
Also when I select NB or cal the s-meter pegs and I dont get any audio.
Thanks George NE2I
---------------------------------------------------------------------- Submissions: [EMAIL PROTECTED] Subscribe: [EMAIL PROTECTED] - subscribe drakelist in body Unsubscribe: [EMAIL PROTECTED] - unsubscribe drakelist in body Hopelessly Lost: [EMAIL PROTECTED] - help in body of message Brought to you courtesy of TLCHost.net http://www.tlchost.net/ ----------------------------------------------------------------------

