Is the 24v supply on the power board workign correctly? Assuming that it is, I would look for correct output on the digital control board. You could have a fault in the bandswitch or the wiring, or one of those pesky Molex connectors.
73 -Jim On Mon, 18 Jan 2010 13:37:50 -0000, Adrian Rees wrote: >Hi All > >I have replaced the single turn pots on the power board, set the 10v and >repaced an IC on the DR7 board. > >The TR7 I have is now reciving fine on all bands except for 10m. On this >band the display shows 10.602 (plus or minus a bit). Any ideas...VCO board ? > >I have started a full alignment, but think I need to fix this first. Any >ideas ? > >Thanks so far for all the help. This is my first excursion in to Drake land, >and I don't think it will be my last ! > >Cheers > >Adrian MW1LCR (Wales) > > >_______________________________________________ >Drakelist mailing list >[email protected] >http://mailman.zerobeat.net/mailman/listinfo/drakelist -- Ham Radio NU0C Lincoln, Nebraska, U.S.S.A. TR7/RV7/R7A/L7, TR6/RV6, T4XC/R4C/L4B, NCL2000, SB104A, R390A, GT550A/RV550A, HyGain 3750, IBM PS/2 - all vintage, all the time! "Give a man a URL, and he will learn for an hour; teach him to Google, and he will learn for a lifetime." HyGain 3750 User's Group - http://groups.yahoo.com/group/HyGain_3750/ http://radiojim(dot)exofire(dot)net http://incolor.inetnebr.com/jshorney http://www.nebraskaghosts.org _______________________________________________ Drakelist mailing list [email protected] http://mailman.zerobeat.net/mailman/listinfo/drakelist