Well, Walker, since I don't see anyone jumping in here to answer you, let me take a stab at it. First, DeOxit should be used sparingly, like a drop at a time, and NEVER sprayed on a bandswitch, or like switch with phenolic wafers.

I use a toothpick (or insulin syringe if I can find them) to put a drop right where I want it on the contact, then work the switch several times to work it in. I put a drop in each hole of a tube socket and work the tube gently to get it distributed. I would advise being careful of using it around front panels, plastic pieces etc without testing a small area. I don't think it is caustic or harmful, but these cosmetic parts are not easily found if damaged.

I don't see too much lubricant, if any, in DeOxit, so don't think it is good long term for use in potentiometers. Caig has other products for that (like Faderlube or something like that).

Maybe that will give you a start, then others can chime in with better details, hi.
73,
Don, WB5HAK

_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist

Reply via email to