Chuck -
Does Tom's kit include C192? I think it does. If not ....
Also D16.
And with the erratic operation, solder joints on C190, etc. Tough
places to solder.
73, Garey - K4OAH
Glen Allen, VA
Drake 2-B, 2-C/2-NT, 4-B, C-Line&
TR-4/C Service Supplement CDs
<www.k4oah.com>
Chuck Grandgent wrote:
My R4B crystal calibrator has been acting erratically.
Often does not function until the R4B has been on for 20 minutes or so.
When I first turn on the calibrator function, I can initially hear it
for maybe 100msec, but it does not stay in oscillation.
And when it's being persnickety, when it does stay in oscillation, it
doesn't sound like a clean sine-wave.
Last night it was acting like this. But just now, it was fine. Came
up right off, sounded fine, and was working OK on 15 meters (didn't
try 10 meters).
I recently did the Hayseed re-capping, so C190 was replaced, and after
the recapping it seemed to really help the crystal calibrator
function, as it was much worse before the recapping.
What else might I check ? I see the calibrator circuitry on the
schematic. My scope is still down for repairs.
Chuck, K1OM
_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist
_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist