Thanks Lee but that was already tried with no effect. When I removed the plastic cover there was no change in the needle position. Warning!! Don't try to remove the metal case to gain access to the movement. You will be sorry you did, pop off the front. I removed the solder lugs to get the meter out of the transmitter, don't take the nuts off the back, desolder the wires instead. John Meyer K8IHY > To: [email protected]; [email protected]; [email protected] > Subject: Re: [Drakelist] T-4XB Meter > From: [email protected] > Date: Sun, 13 Mar 2011 14:15:51 -0400 > > John, > Take a small SOFT rag and wet it, squeeze most water out...then run it > across the meter movement a few times... > I think it will help with any 'static effects' which is what I have had > happen. > > Yes, that is a delicate opertion to straghten the meter pointer, but > you can do it. > Maybe get someone with a very steady hand if you think yours is not > good enough. > 73, > Lee > > > > -----Original Message----- > From: John Meyer <[email protected]> > To: wd8sbb <[email protected]>; drakelist <[email protected]> > Sent: Sun, Mar 13, 2011 2:00 pm > Subject: Re: [Drakelist] T-4XB Meter > > > Ron, > > Thanks for your input. I'm a little afraid to try bending the needle. > It's going to take a steady hand. I wonder if the problem develops > because of some residual or stray magnetism. If that were the case > possibly a degaussing device like used to demagnetize tape heads would > resolve the problem. I believe I have one of those devices around here > some place left over from my days of servicing tape decks. > If I can dig it up it may be worth a try. > > ------------------------------------------------------------ > Date: Sun, 13 Mar 2011 06:24:15 -0700 > From: [email protected] > Subject: Re: [Drakelist] T-4XB Meter > To: [email protected]; [email protected] > > > > John, > I have a meter here too that is the same way. It appears that the > meter movement is made of a disc of magnetized? material inside of a > coil. I was going to carefully bend the needle, but I happened upon > "new" one. It's been some time, but I was going to approach as > follows. Put a close fitting brass tube from the model airplane shop > over most of the needle. With a very fine pointed pliers hold the base > of the needle (above the movement bearing area). Now very slowly bend > the needle in the direction needed. > > BTW this was the meter that left me with a small piece of plastic in my > cornea. Just had my eyes exam this week, and doc tells me I am a very > lucky. > > 73, > Ron WD8SBB > > --- On Sat, 3/12/11, John Meyer <[email protected]> wrote: > > > From: John Meyer <[email protected]> > Subject: [Drakelist] T-4XB Meter > To: [email protected] > Date: Saturday, March 12, 2011, 1:37 PM > > > My T-4XB meter movement is off scale to the left of the zero mark. I > have removed the meter and to my surprise there doesn't appear to be > anyway to zero the needle. Any suggestion to get the needle to rest at > zero would be appreciated. > > Thanks, > > John Meyer K8IHY > > > -----Inline Attachment Follows----- > > > _______________________________________________ > Drakelist mailing list > [email protected] > http://mailman.zerobeat.net/mailman/listinfo/drakelist > > > > > > > _______________________________________________ > Drakelist mailing list > [email protected] > http://mailman.zerobeat.net/mailman/listinfo/drakelist > >
_______________________________________________ Drakelist mailing list [email protected] http://mailman.zerobeat.net/mailman/listinfo/drakelist