That's what my comment would be.  Don't demagnetize!  Your meter needs it's 
magentas and won't work without them.
Sometimes some liquid detergent (dish soap) on a soft cloth is good for 
diffusing static charge on the case.  That or a drier sheet.

KB8BKU,
Darryl in Dayton

On Mar 13, 2011, at 4:51 PM, Ron wrote:

> John,
> Not sure that degaussing would be what you want.  My guess is that the 
> north/south permanent magnet is on that disk.  Then the coil causes a 
> magnetic field that moves the disc and the pointer with it.
> 
> Every analog meter I know has a permanent magnet somewhere and a coil to 
> create a deflection relative to the permanent magnetic field.  The Drake 
> meters are "backwards".   Most meters have a moving coil and stationary 
> magnet.   Drake has a moving magnet and stationary coil.
> 
> I believe that is you degauss the disc, the meter will never work again.  
> Thought anyone else?
> 
> 73,
> Ron WD8SBB
> 
> --- On Sun, 3/13/11, John Meyer <[email protected]> wrote:
> 
> From: John Meyer <[email protected]>
> Subject: RE: [Drakelist] T-4XB Meter
> To: [email protected], [email protected]
> Date: Sunday, March 13, 2011, 1:58 PM
> 
> Ron,
>  
> Thanks for your input. I'm a little afraid to try bending the needle. It's 
> going to take a steady hand. I wonder if the problem develops because of some 
> residual or stray magnetism. If that were the case possibly a degaussing 
> device like used to demagnetize tape heads would resolve the problem. I 
> believe I have one of those devices around here some place left over from my 
> days of servicing tape decks.
> If I can dig it up it may be worth a try. 
> Date: Sun, 13 Mar 2011 06:24:15 -0700
> From: [email protected]
> Subject: Re: [Drakelist] T-4XB Meter
> To: [email protected]; [email protected]
> 
> John,
> I have a meter here too that is the same way.  It appears that the meter 
> movement is made of a disc of magnetized? material inside of a coil.  I was 
> going to carefully bend the needle, but I happened upon "new" one.  It's been 
> some time, but I was going to approach as follows.  Put a close fitting brass 
> tube from the model airplane shop over most of the needle.  With a very fine 
> pointed pliers hold the base of the needle (above the movement bearing area). 
>  Now very slowly bend the needle in the direction needed.
> 
> BTW this was the meter that left me with a small piece of plastic in my 
> cornea.  Just had my eyes exam this week, and doc tells me I am a very lucky. 
>    
> 
> 73,
> Ron WD8SBB
> 
> --- On Sat, 3/12/11, John Meyer <[email protected]> wrote:
> 
> From: John Meyer <[email protected]>
> Subject: [Drakelist] T-4XB Meter
> To: [email protected]
> Date: Saturday, March 12, 2011, 1:37 PM
> 
> My T-4XB meter movement is off scale to the left of the zero mark. I have 
> removed the meter and to my surprise there doesn't appear to be anyway to 
> zero the needle. Any suggestion to get the needle to rest at zero would be 
> appreciated.
>  
> Thanks,
>  
> John Meyer K8IHY
> 
> -----Inline Attachment Follows-----
> 
> _______________________________________________
> Drakelist mailing list
> [email protected]
> http://mailman.zerobeat.net/mailman/listinfo/drakelist
> 
> 
> _______________________________________________
> Drakelist mailing list
> [email protected]
> http://mailman.zerobeat.net/mailman/listinfo/drakelist

_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist

Reply via email to