On Thu, 30 Jun 2011 21:09:05 -0400, Paul Christensen wrote: >As the dial changes from 0 to 500, the PTO's ferrite core moves toward the >back of the receiver. As the core moves rearward, it is also coming nearer >to the AC power transformer. PTO cores are especially susceptible to >magnetic fields. To prove to myself the AC power transformer is the >culprit, I took the PTO assembly in my hands and moved to and from the >transformer.
Ecellent work, Paul! This one is going in my file. 73 -Jim -- Ham Radio NU0C Lincoln, Nebraska, U.S.S.A. TR7/RV7/R7A/L7, TR6/RV6, T4XC/R4C/L4B, NCL2000, SB104A, R390A, GT550A/RV550A, HyGain 3750, IBM PS/2 - all vintage, all the time! "Give a man a URL, and he will learn for an hour; teach him to Google, and he will learn for a lifetime." HyGain 3750 User's Group - http://groups.yahoo.com/group/HyGain_3750/ http://incolor.inetnebr.com/jshorney http://www.nebraskaghosts.org _______________________________________________ Drakelist mailing list [email protected] http://mailman.zerobeat.net/mailman/listinfo/drakelist