I know some of the guys are using third party drivers or something to use
the parallel port with Windows XP, but I have heard that it doesn't work
very well. I just want to get it running per the help file, if I can...

Thanks for the tip, though.

One other interesting fact is that someone pointed out that there is no
IRQ17. I went back and checked and sure enough it is IRQ17. I also checked
the other port on the PCI card and it also says IRQ17, but there are NO
CONFLICTS listed! Everything on those ports works, too. I'm running my radio
on com4 and my rotor on com5, just no cw coming from the DTR...hmm....  : (

73 de Marty

----- Original Message -----
From: "Matt Finlayson" <[EMAIL PROTECTED]>
To: "Marty Ray" <[EMAIL PROTECTED]>; <[email protected]>
Sent: Wednesday, November 27, 2002 4:29 AM
Subject: Re: [DXBase] CW port still not working


> Hi Marty,
>
> I use a laptop to run DXBase and my rig. Since I only have one serial
port,
> I use that to run the rig. I use the parallel port for CW. I paid $25 for
a
> CW-interface cable that goes from the parallel port to the key jack on my
> radio. Works fine.
>
> 73, Matt K9KRY
>
> ----- Original Message -----
> From: "Marty Ray" <[EMAIL PROTECTED]>
> To: <[email protected]>
> Sent: Monday, November 25, 2002 6:15 PM
> Subject: [DXBase] CW port still not working
>
>
> > I have been trying to get the cw port working for a couple of weeks. I
am
> > running windows XP, so I am using DTR on my radio serial port. (The help
> > file states "DXbase allows you to use the same serial port for CW that
is
> > used for your TNC or HF radio provided it does not use the DTR leads.")
> When
> > I set "default DTR High" on the radio port settings, my radio keys up,
> which
> > is correct. However, whe I try to send CW, I get nothing.
> >
> > I have tried setting the com port address in the driver using 'regedit'
to
> > no avail. When I look at my com port address in my
system\hardware\device
> > manger\com4\resources, it shows "I/O range C400-C407" and "IRQ17", so I
> set
> > the com4 data in regedit as follows:
> > "SYSTEM\CurrentControlSet\Services\DriverX\Parameters\Dxb98 COM4\ Port
> Base
> > 0x0000c400 (50176)"
> >
> > PortCount says "0x00000007 (7)"
> >
> > (Default)  says "(value ot set)"
> >
> > and IgnoreConflicts says "0x00000001 (1)"
> >
> > Does anybody have any suggestions. I operate primarily CW, so this
> > limitation may be enough for me to look at another logging program.
> >
> > Thanks for any assistance!
> >
> > Regards,
> >
> > Marty Ray N9SE
> >
> >
> > _______________________________________________
> > DXBase Reflector - Please visit us on the web at www.dxbase.com
> > - - - - - - - - - - - - - - - - - - - - - - -
> > To UNSUBSCRIBE please visit:
> > http://mailman.qth.net/mailman/listinfo/dxbase
> >
>
>

Reply via email to