Hi,

ethtool -i:
driver: i40e
version: 1.2.38
firmware-version: f4.22.27454 a1.2 n4.25 e143f
bus-info: 0000:03:00.1
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: yes

kernel version: 2.6.32-504.16.2.el6.x86_64

I sent my report on 13th December last year to this list, and I think I
was told to wait for an updated driver version and it seems the issue
still persists.

Matyas


On Fri, 15 May 2015, Fujinaka, Todd wrote:

> I haven't seen any replies to this yet and I'm not the expert on the i40e 
> driver, but there are a couple of basic questions we need to ask.
>
> What firmware version are you running? Can you just send us the output of 
> ethtool -i?
>
> What kernel version are you running?
>
> Also, where did you send your earlier report? I'm having trouble finding it.
>
> Todd Fujinaka
> Software Application Engineer
> Networking Division (ND)
> Intel Corporation
> todd.fujin...@intel.com
> (503) 712-4565
>
> -----Original Message-----
> From: Matyas Koszik [mailto:kos...@atw.hu]
> Sent: Thursday, May 14, 2015 9:20 AM
> To: e1000-de...@lists.sf.net
> Subject: [E1000-devel] X710 driver issues
>
>
> Hi,
>
> I've just upgraded to version 1.2.38 of the i40e driver, and still seeing the 
> driver issues I mentioned in an earlier report:
>
> May 14 12:05:30 88 kernel: i40e 0000:03:00.1: TX driver issue detected, PF 
> reset issued May 14 12:05:30 88 kernel: i40e 0000:03:00.1: FCoE capability is 
> disabled May 14 12:05:30 88 kernel: i40e 0000:03:00.1: PHC enabled May 14 
> 12:05:31 88 kernel: i40e 0000:03:00.1: eth4: NIC Link is Up 10 Gbps Full 
> Duplex, Flow Control: None May 14 12:05:31 88 kernel: i40e 0000:03:00.1: 
> eth4: NIC Link is Down May 14 12:05:33 88 kernel: i40e 0000:03:00.1: eth4: 
> NIC Link is Up 10 Gbps Full Duplex, Flow Control: None May 14 12:05:38 88 
> kernel: connection3:0: ping timeout of 5 secs expired, recv timeout 5, last 
> rx 12248432565, last ping 12248437565, now 12248442565 May 14 12:05:38 88 
> kernel: connection3:0: detected conn error (1011) May 14 12:05:38 88 kernel: 
> device-mapper: multipath: Failing path 8:64.
> May 14 12:05:38 88 multipathd: mpatho: sde - readsector0 checker reports path 
> is down May 14 12:05:38 88 multipathd: checker failed path 8:64 in map mpatho 
> May 14 12:05:38 88 multipathd: mpatho: remaining active paths: 2 May 14 
> 12:05:38 88 iscsid: Kernel reported iSCSI connection 3:0 error (1011 - 
> ISCSI_ERR_CONN_FAILED: iSCSI connection failed) state (3) May 14 12:05:40 88 
> kernel: connection1:0: ping timeout of 5 secs expired, recv timeout 5, last 
> rx 12248434595, last ping 12248439595, now 12248444595 May 14 12:05:40 88 
> kernel: connection1:0: detected conn error (1011) May 14 12:05:40 88 iscsid: 
> Kernel reported iSCSI connection 1:0 error (1011 - ISCSI_ERR_CONN_FAILED: 
> iSCSI connection failed) state (3) May 14 12:05:40 88 iscsid: connection3:0 
> is operational after recovery (1 attempts) May 14 12:05:42 88 iscsid: 
> connection1:0 is operational after recovery (1 attempts) May 14 12:05:46 88 
> multipathd: mpatho: sde - readsector0 checker reports path is up May 14 
> 12:05:46 88 multipathd: 8
 :64: reinstated May 14 12:05:46 88 multipathd: mpatho: remaining active paths: 
3 May 14 12:12:14 88 kernel: i40e 0000:03:00.1: FD filter space full, new 
ntuple rules will not be added May 14 12:12:15 88 kernel: i40e 0000:03:00.1: FD 
Filter table flushed and FD-SB replayed.
> May 14 12:12:15 88 kernel: i40e 0000:03:00.1: FD Sideband/ntuple is being 
> enabled since we have space in the table now May 14 12:12:15 88 kernel: i40e 
> 0000:03:00.1: ATR is being enabled since we have space in the table now
>
>
> Matyas
>
>
> ------------------------------------------------------------------------------
> One dashboard for servers and applications across Physical-Virtual-Cloud 
> Widest out-of-the-box monitoring support with 50+ applications Performance 
> metrics, stats and reports that give you Actionable Insights Deep dive 
> visibility with transaction tracing using APM Insight.
> http://ad.doubleclick.net/ddm/clk/290420510;117567292;y
> _______________________________________________
> E1000-devel mailing list
> E1000-devel@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/e1000-devel
> To learn more about Intel® Ethernet, visit 
> http://communities.intel.com/community/wired
>


------------------------------------------------------------------------------
One dashboard for servers and applications across Physical-Virtual-Cloud 
Widest out-of-the-box monitoring support with 50+ applications
Performance metrics, stats and reports that give you Actionable Insights
Deep dive visibility with transaction tracing using APM Insight.
http://ad.doubleclick.net/ddm/clk/290420510;117567292;y
_______________________________________________
E1000-devel mailing list
E1000-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/e1000-devel
To learn more about Intel® Ethernet, visit 
http://communities.intel.com/community/wired

Reply via email to