Hi,
My K2 SN 4307 is under construction.I finished first part succesfully,without
any problems.Ad now I'm in part two, at point with winding toroids.I did it
exacly following manual - I mean RFChokes RFC14, RFC16, RFC11 - number of turns
and dark grey ferrite cores,diamater 9.5mm -all are correct. Because I have LC
bridge, I checked inductivity and I have been suprised.Inductivity of RFC14,
16, 11 are 4x bigger than is written in component list [Appendix A].For example
RFC 14 have 60uH instead 18 uH. My LC bridge is OK, I checked it. I suppose is
something wrong with my toroid cores, Maybe I have got another kind of magnetic
material or mistake is in component list.Could somebody advise me what is more
important, number of turns from manual or inductivity.[In my opinion
inductivity]. I can wind my toroids once more [I have a lot of emanel wire
0.35mm] under control LC device. And what about toroid transformers - I could't
find infomation about its inductivity.
Greetings from Poland
Richard
P.S
Also I have measured another coils and inductors. L33 prewound inductor
and T1050 ,T1005 inductors are correct