Thanks Jim, but that is NOT the problem. I have had both the serial port and K3's RS232 set to both 19200 b and also 38400 b and get the same results.
I initially had the problem because my serial port was set to 19200 b and my K3's RS232 was set for the default of 4800 b. After I changed RS232 to 19200 b, the K3 and N1MM communicated excellent. AFTER updating the K3 firmware to 4.03, again, the K3 and N1MM would not communicate. I am in the process of reverting the K3 firmware back to 3.xx. Thanks Jim and 73, Tom - W4BQF -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Jim Brown Sent: Tuesday, August 03, 2010 2:16 PM To: [email protected] Subject: Re: [Elecraft] K3 and N1MM Logger On Tue, 3 Aug 2010 12:28:54 -0400, Tommy Alderman wrote: > It was working just fine right after I reset the >RS242 to the correct (19200 b) baud rate; then I updated to the beta 4.03 >firmware and now it does not talk to N1MM again. That's the problem. You must set BOTH the K3 and N1MM to the SAME baud rate. Changing it is what made it spit up. Like Guy, I use 38,400. Slower speeds also work. 73, Jim K9YC ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html