I am trying to get a better understanding of the P3 signal level scale (left 
vertical scale) with respect to absolute signal levels and the S meter readings.

I have my REF LVL set to -132 dBm.  My first question is: what is a reasonable 
setting?  I merely am guessing at the value of -132 dBm and also I am not quite 
sure how accurate this is.  According to the P3 manual, this is essentially the 
signal strength at the antenna terminal of my K3 (taking into account the pre 
amplifier which I happen to have Off).

Also, I was monitoring a signal using the PEAK reading capability of the P3 and 
noticed that this particular SSB signal on 17 meter band this morning read peak 
about -100 dBm or about a 32 dBm strength over the minimum reading on the 
scale.  I would like to equate this to a rough idea of an S meter reading.  By 
my calculations, this should be a little bit above an S4 reading.  Can someone 
confirm that I am in the right ball park?

Thanks for the help.
73, phil, K7PEH

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to