Don't forget about the power factor.  The simple power supplies in most 
tube-type amplifiers have pretty low power factors.  I've never measured it, 
but my AL-82 once blew the 15 A 240 V fuses, which suggests PF was less than 
about 0.7.  

As the KPA-500 uses an unregulated 60 V linear supply (just like the HV 
supplies in the tube-type amplifiers), it probably also has a power factor in 
the 0.7 range, and probably draws 11-12 A at 120 V.  A dedicated 20 A circuit 
would improve regulation.

73,

Scott K9MA



Scott Ellington
Madison, Wisconsin
USA



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html