More fiddling and I came up with: PC020;MD3;TX;KYWN1IRB;RX;MD1;PC100;RX;RX;
This seems to work. With out the three "RX" I was finding it to be intermittent as to whether or not it came out of TX as noted by the red TX LED remaining eliminated. With less RX commands I also noticed that when stuck in TX if I pressed the M1 button to re-execute the macro it would simply come out of TX and then run the macro if I pressed the button again. Seems weird and glitchy to me. I wish it would come out of TX at the first RX command instead of having to catch it on the 3rd. I have the CONFIG:CW WGHT option automatic VFO offset (tap 5) set and it auto switches 600Hz up or down depending one whether I am in USB or LSB. I also removed the KS017 as the first time I run the macro it is set. It seemed redundant and cleaner with out it. Thanks all for the help. Scott - N1IRB -- View this message in context: http://elecraft.365791.n2.nabble.com/CW-ID-macro-on-SSB-tp6025949p6028089.html Sent from the [K3] mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html