Daniel,
The inductance of the RF Choke toroids measured at DC or low frequencies
may not agree with the published inductane which is measured at a higher
frequency. Those RF Chokes are not critical, they just need to block
the RF flow and the bypass capacitor takes care of the rest.
The inductors that are critical are those in the Low Pass Filter. In any
case, wind them as instructed in the manual and spread the turns over
85% of the core and they will work. There are over 7000 K2s out there
working fine with the toroids wound as instructed in the manual.
73,
Don W3FPR
On 1/1/2013 9:14 AM, Daniel Heise wrote:
Dear K2-Experts,
I´m just assembling my K2, and it´s true: It really is addictive :)
After winding my first toroid inductors, I measured their inductivity
with an atlas LCR40 component analyser before I soldered them into the
RF board.
Though I closely adhered to the manual, the measured inductivities are
almost twice as high than the values stated in the manual (on the
parts list in appendix A).
It was good to read on the elecraft homepage, that the inductivities
are not too critical for the entire function of the transceiver. But
I´m still wondering if anyone else measured the inductivities of the
toroid inductors and made similar experiences...
73, Daniel
DL6MCL
Goettingen, Germany