On page 48 of the K2 manual the S-meter alignment is done. I was able to
get the Cal S low done just fine. When I then moved on to the Cal S HI (
with the RF gain fully counter clockwise) I was not able go get any
segments of the S meter to light up. I adjusted the VFO full circle and
not one segment of the S meter would light up. The AGC voltage was
adjust to 3.80 volts DC without any problem. Also I read on the list of a
similar problem and Don suggested to check RP6 pin's 9 and 10 and U6
pin 3 (all on the control board) I reheated and soldered these, actually
all the pins on U6 and RP6 and this did not solve the problem. Just
wondering what the next step would be?MikeVE3WDM
______
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html