On page 48 of the K2 manual the S-meter alignment is done. I was able to
 get the Cal S low done just fine. When I then moved on to the Cal S HI (
 with the RF gain fully counter clockwise) I was not able go get any 
segments of the S meter to light up. I adjusted the VFO full circle and 
not one segment of the S meter would light up.  The AGC voltage was 
adjust to 3.80 volts DC without any problem. Also I read on the list of a
 similar problem and Don suggested  to check RP6 pin's 9 and 10 and U6 
pin 3 (all on the control board) I reheated and soldered these, actually
 all the pins on U6 and RP6 and this did not solve the problem. Just 
wondering what the next step would be?MikeVE3WDM                                
          