Good evening Don, I checked the solder connections on Q12 and U2 all were good and I even reheated each connection allowing it to flow. I also checked for proper orientation for U2 and that's ok as well. D1 is good with band facing toward Q12 and to me that is the proper direction. As for CAL S LO the value at which the first bar goes out is 255 and comes back on at 000 As for CAL S HI I am not able to get any of the bars on the meter to light up so I do not have a value for you. Thank very again for your time. Mike VE3WDM
-- View this message in context: http://elecraft.365791.n2.nabble.com/K2-meter-alignment-issue-tp7574472p7574519.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html