GM: If you are looking for a unit to provide remote AC power switching, checkout the Professional 4-port Remote Power Switch from Ambery (Model IP-P3) see http://www.ambery.com/prreposwphco.htm
It can be remotely controlled via phone or web control and provides four separately switched AC outlets. In our remote station, I have 6 outlet power bars plugged into the first three switched AC outlets and a separate primary power relay controlled by the 4th outlet. The K3 power supply goes to the first power bar, other accessories (1216H & L from Microbit) and T2X rotators go to the 2nd & 3rd power bars and the 4th is used to control primary power to the KPA500. Ours has been in use for over a year (using only internet control) and has operated without any problems. 73, Doug VE3MV On 2013-Nov-03, at 10:07 PM, iain macdonnell - N6ML <[email protected]> wrote: > On Sun, Nov 3, 2013 at 12:37 PM, Jim - KE8G <[email protected]> wrote: >> Hello All, >> Well, Murphy raised his ugly head this weekend during the ARRL SSCW contest. >> >> I am operating remote and everything was working fine; the K3 radio, KTA500 >> tuner, and KPA500 amplifier. I was monitoring things via the Elecraft >> software for the tuner and amp. I was on 80 meters and saw a HI SWR warning >> come on the KPA500 software, but not on the KAT500 software. I clicked the >> "Clear Error" area and then received a Comm ERR. >> >> The KPA500 software seemed to freeze and the only thing I could do was >> terminate the program. I re-started the software and it gave me an error >> message saying it could not make contact with the KPA500. I closed all the >> running programs on the remote PC, and then did a re-boot. All is working >> well except for the KPA500 software. I keep getting an error message >> telling me the KPA500 remote is not running and it can't find the amp. >> >> Any ideas that I can do via the Internet? > > Unless you have a way to remotely cycle the AC supply to the KPA500, > you're "SOL". I have a relay on the 220VAC supply going to mine, which > runs off the K3's ACC 12V output, so if I power-cycle the K3, the > KPA500 follows. It is necessary once in a while, when the firmware > hangs. > > 73, > > ~iain / N6ML > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[email protected] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html