I can't speak for Elecraft, but the conversation took place in the last
couple of weeks. I also suggested that they add a "net power" display
mode (forward - reflected) like the Alpha 4510 and Telepost LP-100A
wattmeters have, since this more closely approximates what we understand
as "power output" than forward power whenever the SWR is greater than unity.
On 1/19/2014 9:33 AM, Pierfrancesco Caci wrote:
"Vic" == Vic Rosenthal K2VCO <k2vco....@gmail.com> writes:
Vic> I spoke to an Elecraft employee about bugs in the W2, and he confirmed
Vic> that there are a number of them and that they are planning to come out
Vic> with a new version of the firmware at some point (I don't want to say
Vic> real soon now').
How long ago? Seems firmware hasn't been updated in a while.
Vic> The manual IS incorrect about the alarm needing to be turned on each
Vic> time you power on. In a previous firmware update they made it 'sticky'
Vic> so that once you enable it, it stays enabled until you turn it off.
Many thanks Vic, I can see that Alarm is saved to eprom. I didn't notice
this during previous tests.
I guess fixing the manual is easier than fixing the code ;-)
Pf
--
73,
Vic, K2VCO
Fresno CA
http://www.qsl.net/k2vco/
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html