Nick,

Yes, but it fails when it cools again - something is not making good contact, and it may be residue from the cleaner. I can't be certain of that, but I would get that cleaner residue off and try again.

I would suggest that you remove the cleaner residue from the contacts with acetone - apply it with a brush or cotton swab and immediately wipe the area with a clean cloth of paper towel. Do only a few pins at a time, and do not let the acetone dry on the contacts or board. You may want to mate and unmate the front panel and RF board several times, cleaning between each to hopefully clean some of the 'goop' out of the female header.

If you do not have gold pins on the connector to the front panel, consider asking Elecraft for the gold replacement pins.

73,
Don W3FPR

On 9/7/2015 5:27 PM, Nick Lelyak wrote:
Thanks Don, Guy
appreciate yours quick response.
I found out that problem disappears when front panel warms up to 37 C
and more.
Looks like problem somewhere in FP. To clean main connector I used
Electronic Contact Cleaner. It may works not so good as Deoxit which
is not widely available in Canada. In any case to move on have to buy Deoxit first.
Thanks again

73, Nick VE3FJ


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to