Just a quick thought, are you using a 10:1 probe? If so, you would only be 
getting 5 uV to the scope.

Harlan 
K4HES

Sent from my iPhone

> On May 9, 2017, at 1:49 PM, Randy Moore <wrmoor...@gmail.com> wrote:
> 
> I have a trusty Elecraft XG2 S9 Signal Generator that I've used for years. It 
> produces a nice S9 signal into my K3 at 7040.3 KHz.  I'm trying to use it for 
> trouble shooting a problem on a transceiver kit and there's something that I 
> don't understand.  When I try to measure the 50 uV (S9) signal with a Siglent 
> SDS 1102 CML scope, I get nothing (no signal). I've tried it with the XG2 
> antenna connector open, and with it connected to a good 50 ohm dummy load.  
> I'm measuring at the XG2 antenna connector (center conductor) with the scope 
> probe grounded on the large 50 uV/1 uV switch which is grounded to the XG2 
> circuit board ground.
> 
> I'm able to measure other signals of about the same amplitude and frequency.
> 
> Are my expectations wrong, or am I doing something wrong???
> 
> 73,
> Randy, KS4L
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:Elecraft@mailman.qth.net
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to hsherr...@reagan.com

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to