Ted,
Not Q7 and Q8 in the base K2, but for the KPA100, yes tightening the
screws for Q1 and Q2 should be done after 5 to 10 hours of operation at
greater then 50 watts.
73,
Don W3FPR
On 10/27/2017 11:15 PM, Dauer, Edward wrote:
I vaguely remember reading somewhere that after some number of hours of
operation – maybe 50 – the hardware holding Q7 and Q8 onto the heat sink should
be tightened, I presume to maintain good heat conduction from the tabs to the
sink. But I can’t find that instruction in the manual now. Anyone know where
I might have gotten that notion, or did I just make it up?
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]