The K2 is a kit built by the customer, not Elecraft. 

With respect, my experience is different from Mel's. In many years working 
electronics field and shop service industry have found that re-tightening 
hardware subjected to thermal stress is commonly required by manufacturers. 
Manufacturers routinely do that after a "burn in" period of testing before the 
unit leaves the factory. Elecraft customers are instructed to do it on some 
gear after a period of use. 

The rarity of failures in spite of many thousands of rigs in service suggests 
that Elecraft's recommendations are good ones. 

BTW, when Elecraft has found that a better than metal-to-metal thermal 
conduction is needed, they use thermal pads instead of thermal compounds. The 
pads are entirely adequate and avoid customers handling messy compounds. 

In commercial work, when a manufacturer specifies using a thermal compound, I 
use GC Type 44. It is a non-silicon based compound and so does not 'migrate' 
from where it was placed. My small tube has plenty left and it predates the 
computer "age" -  bought it sometime in the 1970's. Like the old Wildroot Cream 
Oil for hair they mean it when they say a "little dab will do ya" yet it 
remains flexible and never hardens. 

73 Ron AC7AC 

-----Original Message-----
From: [email protected] 
[mailto:[email protected]] On Behalf Of Mel Farrer via Elecraft
Sent: Saturday, October 28, 2017 12:24 PM
To: Cameron Francey; Dauer, Edward; [email protected]
Subject: Re: [Elecraft] PA Transistors Maintenance in K2

Ted,
 If the people at Elecraft have done their job and mounted the transistor 
properly with the correct torque on the mounting hardware procedure, no 
additional maintainance is required. I have been in the industry for a LONG 
time .  Three things to remember in the mounting of any RF or high power 
device.  Flat surfaces, minimual mating gu, and required torque. Lack of any of 
these will kill a device if not correct.  I have never required retorqueing 
parts, with one exception.   In 000 copper wire terminals, the copper does 
relax and needs to be retorqued to achieve a gas tight seal connection, but 
that is in industrial application.  Small RF devices only need the initial 
torque to be correct.

Mel, K6KBE


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to