Hi Don and Bert, as I noticed this evening > troubleshooting nor alignment parts are not same in the different Rev. of K1 manuals.
Our sick K1 is also from 2000... RF board Rev. D, 2000 so I am using the manual Revision D, Dec 1, 2000. Unfortunately when I measured the resistances on page 45 (J7, J8 test points) I found the J7 pin 6 has 5.6kOhms to GND but table on page 45 says it should be >100k. What makes me confusing is that when I opened the later manual Revision F, January 24, 2002 I found that in the same table on page 45 the value of J7 pin 6 should be 5-7kOhms which souns ok compare to my measured value 5.6kOhms... ?! Don can you let me know some hints what it could means in that case please? The rest values are same in both tables and measured values are also corresponding to it. Bert I will send you the proper manual for your K1 (we have same Rev. ) > Revision D, Dec 1, 2000 by email. I got it from Don (many thanks Don!!) Thanks for help in advance. 73 Petr ----- 73 - Petr, OK1RP "Apple & Elecraft freak" B:http://ok1rp.blogspot.com MeWe: https://bit.ly/2HGPoDx MeWe: https://bit.ly/2FmwvDt -- Sent from: http://elecraft.365791.n2.nabble.com/ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html