On 8/7/2019 11:02 AM, Michael Arnold wrote:
This method may result in some low-level 60 and 120 Hz audible ground loop hum 
when AC powered, particularly with the powered speaker connected,

Power line hum and buzz can be prevented by 1) getting power for all interconnected equipment from the same AC outlet, or from outlets whose Green Wires are bonded together, AND 2) bonding from chassis to chassis of all interconnected equipment, AND 3) proper bonding of all grounds in the home, including ground from that interconnected equipment in the shack. All three are necessary. There's a tutorial on this at k9yc.com/publish.htm