Hello,

I have been working on a new K2 the last couple of months. SN 7927

Yesterday I finished and installed the KSB2 SSB adapter.

I have been mostly listening. All seemed normal with receive on 80 and 40 
meters, on LSB.

But, as soon as I go to USB on any band below 21 mhz, or LSB 21 and above, the 
S meter goes to nearly full scale, and the receiver is desensitized. If I turn 
off the AGC, the receiver seems to work normally receiving both LSB and USB.

I have checked the BFO values and used the default value of 4916.3 for USB and 
4913.5 for LSB.

No setting of the USB BFO seems to solve the issue. I can change the value and 
drop the S meter with AGC on and hear the Receiver apparently return to normal, 
but then I can’t tune USB and the number I am using then is close to the LSB 
value.

Why the receiver works normally with AGC off, but not with AGC on on OP1 filter 
is puzzling to me. Everything is normal on the K2’s internal filters.

I assume this has something to do with the crystal filter and BFO frequencies, 
but no idea where to go.

Any ideas would be appreciated.

73 Chuck K8LBH

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected] 

Reply via email to