Ian, Have you tried checking the small toroid RF Chokes for shorts to the crystal can? That is a common cause of the problem you describe. Just stick a small piece of paper between the chokes and the crystal cans for a quick check - if the receiver comes to life, rewind the chokes (being careful not to scrape the wire insulation).
You can ignore the voltage at U4-3 until after you have properly adjusted the carrier balance - that voltage depends on the exact setting of the balance pot. 73, Don W3FPR > -----Original Message----- > > Hi all, > Well I have finally started looking for the fault on my SSB board after > about 9 months! For some reason I have no receive when the board is > plugged in. If I short out pins 1 and 3 of J9 and J10 I get receive no > problem, so it would appear to be a fault on the SSB board. > I have checked the crystals to ground, all seems OK. I have checked the > voltages on the pin diodes and again, all would seem well. In fact, > other than a few small stray voltages, the only major anomaly I can find > is a voltage on U4-3 of 6V on receive. The manual states 0.6 volts. > I would love any thoughts to point me in the right direction please? > > 73 Ian > -- No virus found in this outgoing message. Checked by AVG Free Edition. Version: 7.5.432 / Virus Database: 268.17.0/639 - Release Date: 1/18/2007 6:47 PM _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com