The K3's dBV function is a *relative* measure. It must be set to
whatever reference you wish by first using AFV. The calculation
measurement is true RMS. It is used for measuring things like MDS, AGC
slope, roofing filter attenuation and so forth.
So what's the correct procedure for measuring MDS using the internal meter
and a XG2 oscillator?
See the MDS procedure in the XG2 manual, pages 5-7. You can use the K3
AFV and/or dBV functions instead of an external meter.
73,
Lyle KK7P
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com