<<<If there is enough macro memory, it will work.>>>

Well there isn't, the limit on a Macro is 120 characters. The problem is,
you can't just set an EQ band with a single command. You need to step UP or
DN.

For example just to set 50Hz to +12 you would use:

MN009;<Selects TX EQ Menu>SWT53;<Resets EQ bands to zero>SWT11<Selects 50Hz
EQ Band>UP;UP;UP;UP;UP;UP;UP;UP;UP;UP;UP;UP<Step Up 12 times>;MN255;<Exits
Menu>

As you can see, doing all eight bands would be a lot longer then 120
characters.

I did send a long string with the K3 Utility test window, so that is an
option. Put the string in a file then copy and paste into K3 util.

I will probably just define buttons on HRD to do this. Unless it has a
limit. :>)
-- 
View this message in context: 
http://n2.nabble.com/K3-transmit-equalizer-settings-tp4615446p4622959.html
Sent from the [K3] mailing list archive at Nabble.com.