At 12:41 AM 2/1/2010, you wrote:
These are the errors here's seeing so it looks Dr. Baker's post
indicates a possible bug:

I get the error as follows:
P-Well contact is floating
N-Well contact is floating
P-Well contact 'sub...@89' not connected to ground
N-Well contact 'w...@0' not connected to power

The ERC well check is not intended to work on schematics, only layout. I don't see how it could work on schematics, since there are no well contacts and well areas in schematics, and that is what is being checked.

As far as the CNFET layout that is failing, could you please send this to me for analysis.

   -Steven Rubin

--