On 03/23/2016 06:58 AM, Tanay Gahlot wrote: > andy pugh <bodgesoc@...> writes: > >> Whether you would add an extra optional parameter to G33.1 or define a >> G33.2 would be a decision to be made. >> > Hello, > I will add an optional parameter in G33.1 which will wrap it in a six > line utility > as pointed by Gene to perform pecking. Though i am not quite sure how to > handle the spindle synchronization issue pointed by Neil. Also how will i > provide working example? Are there any guideline to write tests? > A pecking routine should not need to re-synchronize the Z to the spindle. Just keep the Z in synch, and flip the spindle from forward to reverse, and the Z should follow the thread pitch up and down. So, you would synch to the spindle once, and then remain synched for all of the pecks.
Jon ------------------------------------------------------------------------------ Transform Data into Opportunity. Accelerate data analysis in your applications with Intel Data Analytics Acceleration Library. Click to learn more. http://pubads.g.doubleclick.net/gampad/clk?id=278785351&iu=/4140 _______________________________________________ Emc-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-developers