>Sender: [email protected] >Received: from ruebert.ieee.org (ruebert.ieee.org [199.172.136.3]) by >hil-img-6.compuserve.com (8.6.10/5.950515)
WOODS, RICHARD wrote: >A Notified Body for EMC has told us that we must keep the test sample >for 10 years. Since there is nothing in the Directive that requires >samples to be kept, we find this request to be unacceptable. We have a >TCF and understand that it must be kept for 10 years after production >ceases. Has anyone else encountered this type of requirement by a >Notified Body? The answer is no. I do not see any sense in doing it. Documentation, tcf and so on must be kept 10 years after the last unti was placed on the market or taken into service. George ******************************************************************** * Dr. Georg M. Dancau * HAUNI MASCHINENBAU AG * * [email protected] * EMC Lab * * TEL: +49 40 7250 2102 * Kampchaussee 8..32 * * FAX: +49 40 7250 3801 * 21033 Hamburg, Germany * ******************************************************************** * home: Tel: +49 40 738 51 07 * Lohbruegger Landstr. 82 * * Fax: +49 40 730 11 99 * 21031 Hamburg, Germany * ********************************************************************